CJGHT - SKASOL MB-5

  • MSDS: CJGHT
  • Manufacturer: SKASOL INCORPORATED
  • Product Name: SKASOL MB-5
  • National Stock Number: 6850-00-RX9-8024
Product Identification

Product ID:SKASOL MB-5
MSDS Date:01/10/1997
FSC:6850
NIIN:00-RX9-8024
Status Code:A
MSDS Number: CJGHT

Responsible Party
SKASOL INCORPORATED
1696 W GRAND AVE
OAKLAND, CA 94607-1607
US

Emergency Phone: 510-839-1000

Info Phone: 800-424-9300

Preparer: JESSICA CORRIGAN

Cage: 0JRJ9

Contractor
SKASOL INCORPORATED
OAKLAND, CA 94607-1607 US

Telephone: 510-839-1000

Cage: 0JRJ9

Ingredients

POLY(OXYETHYLENE (DIMETHYLAMINO) ETHYLENE- (DIMETHYLAMINO)

CAS: 31075-24-8

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, HEART,
RESPIRATORY AND GASTRINTESTINAL TRACTS (HMIS). ACUTE - INHALED:
MIST OR LIQUID WILL CAUSE MAJOR IRRITATION OF THE RESPIRATORY
TRACT. LARGE AMOUNTS WILL CAUSE BURNING SENSATION IN NOSE AND
THROAT. CONTACT WITH EYES OR SKIN: CAUSES SEVERE DAMAGE TO EYES,
SKIN IS MORE RESISTANT, BUT PROLONGED EXPOSURE CAN CAUSE
IRRITATION. MAY BE ABSORBED THROUGH SKIN IF CONTACT IS P ROLONGED.
SWALLOWED: WILL CAUSE BURNING AND DAMAGE TO MOUTH, ESOPHAGUS AND
STOMACH. ON THE BASIS OF AVAILABLE INFORMATION, ACUTE EXPOSURE IS
NOT EXPECTED TO CAUSE ANY SIGNIFICANT HEALTH EFFECTS. CHRON IC -
UNKNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SEVERE IRRITATION, PAIN, NAUSEA, VOMITING, EYE
REDNESS, TEARNING, BLURRED VISION, BURNING SENSATION, EYE DAMAGE,
COUGHING, CHEST DISCOMFORT, HEADACHE, DIFFICULTY IN BREATHING

First Aid

First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALATION: REMOVE
VICTIM TO FRESH AIR. IF NOT BREATHING, PROVIDE RESUSCITATION. IF
BREATHING IS DIFFICULT, PROVIDE OXYGEN. CONTACT A PHYSICIAN OR
POISON CONTROL CENTER. EYE CONTACT: IMMEDIATELY FLUSH WITH WATER
FOR AT LEAST15 MINUTES. HOLD EYELIDS OPEN. GET MEDICAL ATTENTION
IMMEDIATELY. SKIN: FLUSH WITH PLENTY OF WATER. REMOVE CONTAMINATED
CLOTHING. INGESTIO N: DO NOT INDUCE VOMITING. IF CONSCIOUS, DRINK
LARGE QUANTITY OF WATER OR MILK. SEEK MEDICAL ATTENTION. DO NOT
GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.

Fire Fighting

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:WATER, FOAM, CO2, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND RESPIRATORY
PROTECTION
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:DIKE AREA TO CONTAIN THE SPILL. SMALL SPILLS
MAY BE FLUSHED AND DILUTED WITH LARGE AMOUNT OF WATER AND WASHED TO
A SEWER CONNECTED TO A WASTE TREATMENT PLAN. LARGER SPILLS SHOULD
BE CONTAINED AND NEUT RALIZED WITH DILUTE BASE BEFORE WASHING WITH
PLENTY OF WATER TO A SEWER CONNECTED TO A WASTE TREATMENT PLAN. ANY
DOT CONTAINER IS SUITABLE TO HOLD NEUTRALIZED WASTE.
Neutralizing Agent:DILUTE BASE

Handling

Handling and Storage Precautions:STORE IN CLOSED CONTAINER. KEEP AWAY
FROM STRONG BASES, STRONG ACIDS, ANIONIC SURFACTANTS.
Other Precautions:AVOID EYE AND SKIN CONTACT. KEEP OUT OF REACH OF
CHILDREN.

Exposure Controls

Respiratory Protection:WHEN CONDITIONS REQUIRE IT, USE A RESPIRATOR
APPROVED BY NIOSH/MSHA WITH A DUST/MIST FILTER. RESPIRATORY
PROTECTION PROGRAMS MUST MEET OR EXCEED THE REQUIREMENTS OF TITLE
29 CFR 1910.134
Ventilation:LOCAL EXHAUST VENTILATION SHOULD BE SUFFICIENT TO MINIMIZE
EMPLOYEE EXPOSURE TO MIST BELOW OSHA PEL
Protective Gloves:NITRITE, NEOPRENE OR NATURAL RUBBER.
Eye Protection:CLOSE FITTING CHEMICAL SAFETY GOGGLES WITH A FACE SHIELD
IF NEEDED.
Other Protective Equipment:RUBBER BOOTS WITH SAFETY TOES, RUBBER
APRONS, PLASTIC HARD HATS SHOULD BE USED WHEN NECESSARY TO PREVENT
SKIN CONTACT.
Work Hygienic Practices:PROTECTIVE CLOTHING AND USE OF EQUIPMENT MUST
BE IN ACCORDANCE WITH TITLE 29 CFR SECTIONS 1910.132 AND 1910.133
Supplemental Safety and Health
CHEMICAL FEED PUMPS SHOULD BE ROUTINELY WASHED OUT WITH WATER. PLASTIC
TUBING AND FITTINGS SHOULD BE FREQUENTLY INSPECTED FOR LEAKS AND
CLOGS. PROVIDE EMERGENCY EYE WASH STATIONS AND EMERGENCY SHOWER
FACILTIES NEAR USE AND HANDLING AREAS.

Chemical Properties

HCC:C1
Boiling Pt:=101.1C, 214.F
Spec Gravity:1.008
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR RED LIQUID, DETERGENT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG BASES, STRONG ACIDS, ANIONIC SURFACTANTS.
Stability Condition to Avoid:DO NOT MIX WITH STRONG BASES, STRONG
ACIDS, ANIONIC SURFACTANTS.

Disposal

Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL,
STATE, AND FEDERAL LAWS AND REGULATIONS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:PROD HAS NOT BEEN TESTED FOR ECOTOXICITY. VENT: LIMS &
GUIDELINES. NEED FOR VENT SYS SHOULD BE EVALUATED BY PROFESSIONAL
INDUSTRIAL HYGIENIST, WHILE DESIGN OF SPECIFIC VENT SYS SHOULD BE
CONDUCTED BY PROFESSIONAL ENGINEER. APPEAR/ODOR: FORMED SHAPES
WITH OR W/OUT NON-WOVEN/VINYL FACINGS; NO SIGNIFICANT ODOR. VOC:
NOT APPLICABLE. HAZ DECOMP PRODS: MONOXIDE, CARBON PARTICLES,
FORMALDEHYDE & TRACES O F HYDROGEN CYANIDE. OTHER INFO: OUT &
SPRAYING MAY GENERATE AIRBORNE FIBER CONCS REQUIRING HIGHER LEVEL
OF RESP PROT. FOR EXPOS UP TO 50 TIMES ESTABLISHED EXPOS LIMS, USE
NIOSH APPRVD FULL-FACE RESP, RATED N99 OR HIGHER.

Transport

Transport Information:U.S. DOT SHIPPING CLASSIFICATION: NOT CLASSIFIED
AS HAZ MATL. TOXICOLOGICAL INFO: ADVERSE CLINICAL, FUNCTIONAL OR
RADIOGRAPHIC SIGNS OF EFTS OF EXPOS TO MMMFS (FIBER GLASS IS MMMF)
IN THESE WORKERS." IN ADDN TO REPORTING CURRENT RSLTS,
INVESTIGATORS CONCLUDED THAT "RSLTS OF INVESTIGATION ARE CONSISTENT
W/PREVIOUSLY REPORTED CROSS-SECTIONAL STUDIES THAT HAVE FAILED TO
FIND PERSUASIVE EVID OF RESP E FTS OF MFR OF MMMF." 1990 UPDATE OF
MORTALITY STUDY OF U.S. FIBER GLASS MFG WORKERS REPORTED SM BUT
STATISTICALLY SIGNIFICANT EXCESS IN RESP CANCER AMONG WORKERS. THIS
INCR, HOWEVER, COULD NOT BE ASSO C W/EXPOS TO FIBER GLASS (SARA
REGS)

Regulatory

SARA Title III Information:THERE ARE NO CHEMS IN THIS PROD REGULATED BY
SARA 313, CERCLA OR TSCA 12(B). TRANSPORT: BECAUSE NO RELATIONSHIP
FOUND BETWEEN DOSE RESPONSE OR LENGTH OF EMPLOYENT & INCR IN CANCER
RATES. STUDY HAS BEE N EXPANDED, WHILE CONTINUING TO MONITOR
WORKERS' CANCER RATES, TO IDENTIFY & EXAMINE POSS FACTORS (EG,
SMKNG) CONTRIBUTING TO INCR IN RESP CANCER. PREVIOUS CHRONIC ANIMAL
INHAL STUDIES HAVE NOT SHOWN ANY IRREVERSIBLE DISEASE EFTS RELATED
TO BLDG INSULATION FIBER GLASS EXPOS. FIVE PREVIOUS CHRONIC INHAL
STUDIES EXPOSING ANIMALS TO SPEC PURPOSE FIBER GLASS HAVE ALSO NOT
SHOWN ANY EVID OF DISEASE. CN TCT NEHC FOR MORE INFO .
Federal Regulatory Information:OSHA PELS IDENTIFIED IN INGRED SECTION
ARE BASED UPON REVISED PELS OF 1988. OSHA HAS BEEN CHALLENGED BY
COURTS TO PROVIDE MORE INFO ABOUT ITS UPDATE PROCESS. UNTIL THESE
ISSUES ARE RESOLVED, SCHULLER WILL CONTINUE TO LIST THESE PELS.
THIS PROD & ITS COPONENTS ARE LISTED ON TSCA SUBSTANCE INVENTORY.
State Regulatory Information:CALIFORNIA PROPOSITION 65 - SUBSTANCES
KNOWN TO THE STATE TO CAUSE CANCER: GLASSWOOL FIBERS (AIRBORNE
PARTICLES OF RESPIRABLE SIZE).